用新唐N76E003的ADC测量,串口显示连续跳,能改进一下吗?
最近在做N76E003的ADC,参考电压是VDD,采用电阻分压,ADC脚直接测量,用万用表显示是4.2V,在串口助手里显示如下:Voltage:00004.29
Voltage:00004.14
Voltage:00004.25
Voltage:00004.29
Voltage:00004.14
Voltage:00004.29
Voltage:00004.16
Voltage:00004.18
Voltage:00004.29
Voltage:00004.14
Voltage:00004.29
Voltage:00004.27
Voltage:00004.14
Voltage:00004.29
Voltage:00004.14
Voltage:00004.23
显示不稳定,同样的电路用ST的003,显示的是固定数值,不跳变。
程序是根据官方例子改的,
官方例子如下:
void main (void)
{
InitialUART0_Timer1(115200);
Enable_ADC_AIN0; // Enable AIN0 P1.7 as ADC input, Find in "Function_define.h" - "ADC INIT"
while(1)
{
clr_ADCF;
set_ADCS; // ADC start trig signal
while(ADCF == 0);
printf ("\n Value = 0x%bx",ADCRH);
printf ("\n Value = 0x%bx",ADCRL);
Timer0_Delay1ms(1000);
}
}
我改的读取结果函数:
unsigned long GetResult(void)
{
clr_ADCF;
set_ADCS;
while(ADCF == 0);
temp_H=ADCRH;
temp_L=ADCRL;
ADCtemp=((temp_H<<4)|(temp_L&0x0F));
return ADCtemp;
}
用的AIN7
Enable_ADC_AIN7; //PIN14
Timer0_Delay1ms(100);
data1 = GetResult(); //Read the 14th Pin's voltage
Timer0_Delay1ms(100);
data1 = GetResult(); //Read the 14th Pin's voltage
串口显示.....
各位知道结果跳变的原因吗?感谢。
精度和噪音问题。你做个滑动窗口中值+均值,牺牲采样率来提高精度。 100ms读一次,这个应该够慢的了。
把晶振频率降下来吗?例子里看不见晶振设置在哪里,{:sad:} ADC时钟不支持分频是个杯具,把系统时钟分频到4M以下再看看 低电压测量出来的值不准,将ADC测量后前几次的值丢弃,不丢结果就一直不准确。另外ADC测量时频率降一下,有一个例子是0X02分频,我搞了一个0X04,测量完后,再恢复原状。
结果有时还跳,比以前情况好点了。{:sad:} 這種情況只能軟件濾波了,畢竟硬件條件只能這樣了。
不過話說回來,我一直覺得臺系MCU的ADC的指標標得有些浮誇,還是歐美的指標保守。 是不是与单片机的ADC输入阻抗有关系? 不用12位的ADC,舍弃2位,用10位的ADC,效果会好一些。{:smile:} 有个有趣的要求:
哦,有空试试楼上的方法, arm7tdmi 发表于 2018-8-24 16:42
哦,有空试试楼上的方法,
楼主啊你消失了吗??后来问题解决了吗?? 天空の城 发表于 2019-5-7 10:36
楼主啊你消失了吗??后来问题解决了吗??
用10位的ADC,效果差不多了。